Quick Overview

The StatPacks G3+ Breather Oxygen Bundle is an integrated airway management carriage system designed for certified EMS personnel to transport and deploy a complete respiratory care suite, including a D-sized oxygen cylinder, as a single-responder unit in pre-hospital emergencies.

The G3+ Breather system consolidates advanced airway equipment and oxygen delivery into one backpack-style chassis, eliminating equipment fragmentation during deployment. The front-loading clamshell compartment opens flat, providing simultaneous visual and physical access to the G3+ Oxygen Module and all user-stocked medical modules without opening a secondary bag. This design is purpose-built for confined or austere environments, including stairwells, tactical operations, and mass casualty incidents where speed of access directly affects patient outcomes.

The pack's ergonomic suspension system includes fully adjustable shoulder, sternum, and waist straps, distributing the load of a full D-cylinder across the operator's torso to reduce fatigue during movement. The pathogen-resistant G3+ tarpaulin exterior supports rapid decontamination with department-approved disinfectants following patient contact. Oversized YKK zippers with high-visibility pulls allow gloved, non-slip access in low-light conditions, maintaining operational readiness under field conditions where fine motor precision is degraded.

Readiness sustainment is structured across three intervals: post-call restocking and exterior wipe-down, daily shift inspections covering zippers, hardware, straps, and cylinder pressure, and monthly deep cleaning with full structural assessment. Internal layout standardization across the service is operationally critical, ensuring any provider can locate equipment by muscle memory without searching, which is a non-negotiable requirement in high-acuity respiratory emergencies.

---

Field Application Steps

1. PRE-DEPLOYMENT INSPECTION: Before exiting the vehicle, visually confirm the pack is fully stocked and the oxygen cylinder pressure gauge reads above the minimum service level, which is 500 PSI or per local protocol. Do not deploy with a cylinder below operational threshold.

2. DON AND SECURE THE PACK: Place the backpack on your back and adjust the shoulder, sternum, and waist straps until the load is distributed securely across your torso. A properly fitted suspension system reduces fatigue and prevents injury during movement through stairwells or confined access routes.

3. STAGE THE PACK AT THE PATIENT'S SIDE: Position the pack near the patient's head on a stable surface. Lay it on its back and use the oversized zipper pulls to open the main compartment fully into a clamshell configuration, exposing all contents simultaneously.

4. INITIATE OXYGEN DELIVERY: Access the G3+ Oxygen Module and unzip or unbuckle the retention straps securing the D-cylinder. Open the main valve, attach the appropriate delivery adjunct such as a non-rebreather mask, set the prescribed flow rate, and apply to the patient.

5. TRANSITION TO ADVANCED AIRWAY MANAGEMENT: Access adjacent user-stocked modules as dictated by patient condition and your agency's protocol. The open clamshell layout enables seamless transition to nebulizer treatment, BVM ventilation, or advanced airway placement without opening a separate bag.

6. POST-INCIDENT SHUTDOWN AND RECOVERY: Close the oxygen cylinder valve and bleed the regulator. Conduct a rapid inventory of all remaining equipment and secure all components before movement.

7. DECONTAMINATE AND RETURN TO SERVICE: Perform a thorough exterior wipe-down using your department-approved disinfectant, focusing on all fluid contact areas. Replace all expended medical supplies before clearing the scene or returning the pack to the vehicle.

---

STATPACKS G3+ Breather Oxygen Bundle – Integrated ALS Response System

Equip Yourself: STATPACKS G3+ Breather Oxygen Bundle – Integrated ALS Response System

Ensure you have the right gear before an emergency strikes.

View Product
LEGAL DISCLAIMER & SAFETY WARNING:
The information provided in this Luminary Global Field Manual is strictly for educational and informational purposes. It is not a substitute for formal medical, tactical, or professional training. In the event of a medical emergency, immediately seek professional help or contact emergency services. Luminary Global assumes no liability for the misuse of equipment, improper application of techniques, or any injuries/damages resulting from the use of these guidelines. Always rely on your official agency training, local laws, and established protocols during a crisis.